Instruction manual tn_us, Sauter gmbh, 2t v h – KERN & SOHN TN 300-0.01US User Manual

Page 2

Advertising
background image

Sauter GmbH

Tieringerstr. 11-15
D-72336 Balingen
E-Mail: [email protected]

Tel: +49-[0]7433- 9976-174
Fax: +49-[0]7433-9976-285
Internet: www. sauter.eu

Instruction Manual

TN_US

TN_US-BA-e-1112

2

ceramics, epoxies, glass and other ultrasonic
wave well- conductive materials.

-

Various transducer models are available for
special applications included coarse grain
material and high temperature applications.

-

Zero adjustment function,

Sound velocity calibration function
-

Two- point calibration function

-

Two measurement modes: Single point mode

Scan mode
-

Coupling status indicator showing the coupling
status

-

Battery indication indicates the rest capacity of
the battery

-

“Auto sleep” and “Auto power off” function to
conserve battery’s life
Optional software for TN xx0.01 US to transfer
the memory data to PC

-

Optional thermal mini- printer to print the
measured data via RS-232 port, available for
TN xx0.01 US.


1.3 Measuring principle

The digital ultrasonic thickness gauge determines the
thickness of a part or a structure by accurately measuring
The time required for a short ultrasonic pulse generated by
a transducer to travel through the thickness of the material,
to reflect from the back or inside surface and be returned
to the transducer. The measured two- way transit time is
devided by two to account for the down-and-back travel
path, and then multiplied by the velocity of sound in the
material. The result is expressed in following relationship:

2

t

v

H

×

=

Where: H ----˃ thickness of the test piece
v ----˃ sound velocity in the material
t ----˃ the measured round-trip transit time

1.4 Configuration

Table 1-1

No.

Item

Qua
ntity

Note

1

Main body

1

2

Transducer

1

Model
ATU-
US 10
90°

3

Couplant

1

4

Transport case

1

5

Instruction manual

1

Stan-
dard
configu
ration

6

Alkaline Battery

2

AAsize

9

Transducer: ATU-
US 01

10

Transducer: ATU-
US 02

Optio-
nal
configu
ration

11

Transducer: ATB-
US 02

see
table
3-1

12

Mini Thermal
printer

1

13

Print cable

1

14

Data Pro Software

1

15

Communication
cable

1

für PC
at
Mod.
TN300
-0.1US



1.5 Operation conditions

Temperature: -20°C up to +60°C

Storage temperature: -30°C up to 70°C

Relative humidity: ≤ 90%
In the surrounding environment any kind of vibrations
should be avoided, as well as magnetic fields, corrosive
medium and heavy dust.

2. Structure feature

1 Main body
2 Keypad
3 LCD Display
4 Pulser socket
5 Receiver socket
6 Contol plate
7 Communication port
8 Label
9 Battery cover
10 Sensor
















2.1 Main screen








POWER: 2 X 1.5V

SN:

ULTRASONIC

THICKNESS GAUGE