PREVENTATIVE MAINTENANCE PROCEDURES

1. Change fluid in RESERVOIR ONLY every 36 months.

a) Check fluid only when jacks are fully retracted.
b) Always fill the reservoir with the jacks in the fully retracted position. Filling reservoir when jacks are extended will cause
reservoir to overflow into its compartment when jacks are retracted.
c) When checking fluid level, fluid should be within ¼” of fill spout lip.

2. Check the fluid level every month.
3. Inspect and clean all Pump Unit electrical connections every 12 months. If corrosion is evident, spray unit with WD-40 or equivalent

4. Remove dirt and road debris from jacks as needed.

WARNING!

Your coach should be supported at both front and rear axles with jack stands before working underneath.

Failure to do so may result in personal injury or death.

5. If jacks are down for extended periods, it is recommended to spray
exposed leveling jack rods with a silicone lubricant every seven days for
protection. If your coach is located in a salty environment, it is
recommended to spray the rods every 2 to 3 days.

CAPACITY - 22,000 lb.
STROKE - 16 in.
H - 20 1/2 in.
D - 3 3/8 in.
12” SHOE-STANDARD

D

D

D

H

H

H

115842

115841

Fig.1a

Fig.1b

Fig.1c

CAPACITY - 12,000 lb.
STROKE - 15 in.
H - 19 1/2 in.
D - 2 3/8 in.
9” SHOE-STANDARD
12” SHOE-OPTIONAL

CAPACITY - 7,000 lb.
STROKE - 13.75 in.
H - 18 1/4 in.
D - 2 3/8 in.
A - 2 1/2 in.
9” SHOE-STANDARD
12” SHOE-OPTIONAL

CAPACITY - 7,000 lb.
STROKE - 13.75 in.
H - 18 1/4 in.
D - 2 3/8 in.
A - 5 3/4 in.
9” SHOE-STANDARD
12” SHOE-OPTIONAL

D

H

Fig.1d

117179

A

A

113314