Lippert Components LCI Level-Up Motorhome Leveling (2013-present) User Manual

Page 7

Advertising
background image

Rev: 08.11.2014

LCI Level-Up Motorhome Leveling (2013-Present)

Page 7

Controls
Features

• Automatic extension of jacks from full retract position (with automatic ground detection).
• Automatic leveling of jacks.
• Manual leveling of jacks.
• Automatic retraction of jacks (with automatic full retract detection).
• Air bag suspension features (configurable on/off).
• Emergency retract/user alarm mode (jacks not retracted and park brake disengaged).
• Automatic jack error detection and error mode.
• Configuration mode for Air features.
• Configuration modes for Leveling Zero Point.
• Remote operation.

System Wiring Requirements

• Battery power (2 ga. SAE J1127. Type SGX).
• Battery ground (2 ga. SAE J1127. Type SGX).
• Logic power (switched via ignition).
• Power brake signal (open=park brake disengaged, GND=park brake engaged).
• 4-wire harness connecting Controller to Touch Panel.
• Jacks status input-Switched to GND

A. Jacks not all up – switch closed to ground
B. Jacks all up – switch open.

Air and Auxiliary Features

(When Applicable)
System has the option to control external Air and Auxiliary features.
When enabled, the feature works according to the following logic:

• Air bag pressure automatically lowered when starting the auto or manual sequence to maximize lift

of jacks.

• An Auxiliary mode activated when starting an auto retract sequence to fill air bags.
• Auxiliary is active when jacks are all retracted and park brake is disengaged to fill airbags.

The Manual Air Bag Dump/Fill functions as follows:
1. Set park brake.
2. Scroll up twice to “MANUAL AIR CONTROL”.
3. Press enter.
4. Press rear arrow to dump, front arrow to fill.