Lippert Components LCI Level-Up Motorhome Leveling (2013-present) User Manual

Page 13

Advertising
background image

Rev: 08.11.2014

LCI Level-Up Motorhome Leveling (2013-Present)

Page 13

Clockwise for manual override

Counter-clockwise for normal operation

Manual Override - Jacks

In the event that the jacks will not extend or retract, the valves can be manually overridden by using a 5/32”

hex wrench to turn the manual override clockwise on the valve (See Fig. 7). The leveling jacks can then be

extended or retracted. Remember to turn the manual override completely counterclockwise (See Fig. 8)

until it will no longer turn to close the valve after the jacks have been completely extended or retracted. Do

not over-tighten override set screws, as this can damage the valves.

Fig. 7

Fig. 8

Manual Override - Power System

The Lippert LCI Level-Up Motorhome Leveling System can be run with auxiliary power devices like cordless

or power drills. In the event of electrical or system failure, this manual method of extending and retracting

the jacks can be used. A standard handheld drill is all that is required. See the instructions below.

Fig. 9

Fig. 10

1. Remove plastic cap (Fig. 9A).
2. Disconnect or shield power cables on the motor.
3. Using a ½ ” socket and auxiliary drive device, i.e. cordless or power drill, insert ½ ” socket onto coupler

found under plastic cap (Fig. 10A).

4. Run drill in reverse or counterclockwise to retract jacks.

A

A

Advertising