Panel controls 2 – Make Noise René User Manual

Page 6

Advertising
background image

Inputs (Continued)

7. Y- CV Input: control signal at this input generate a number that is added to the

number generated by the Y- Axis Counter, to create the Y coordinate. When René counts

Snake Style, Y- CV selects stored set of coordinates.. Y- CV is normalled to +5V so that with

nothing patched the attenuator acts as an offset generator.

8. Y-CV Input CV Attenuator

Outputs:
10. QCV: The Quantized Control Voltage for the currently active location will appear at this output. QCV

may also yield a Stored Quantized Voltage (if selected on Q Page), in which case the

corresponding location potentiometer is no longer “live.” Value, 4 octaves.

12. Gate X: this output reflects the ProGraMming on the X-Gate Page. When René arrives at a location,

and the location is set to ON (lighted) at the X-Gate PGM Page, this output goes HI for

duration determined by the XCLK width and any ProGraMmed Logic Operations that Axis Clock

or Gate.

When counting SNAKE style, the Gate output is always a skinny pulse (2ms) perfect for

ringing LoPass Gates. Value, 0V or +8V. Gate Y: this output reflects the ProGraMming on the

Y- Gate Page. When René arrives at a location, and the location is set to ON (lighted) at the

Y- Gate PGM Page, this output goes HI for duration determined by the YCLK width and any

ProGraMmed Logic Operations affecting the Axis Clock or Gate. When counting SNAKE

style, the Gate output is always a skinny pulse (2ms) perfect for ringing LoPass Gates. Value,

0V or +8V.

13. Gate Y: this output reflects the ProGraMming on the Y‐Gate Page. When René arrives at a location,

and the location is set to ON (lighted) at the Y‐Gate PGM Page, this output goes HI for duration

determined by the YCLK width and any ProGraMmed Logic Operations affecting the Axis Clock

or Gate. When counting SNAKE style, the Gate output is always a skinny pulse (2ms) perfect

for ringing LoPass Gates. Value, 0V or +8V.

Interface:

14. CV ProGraMming Grid

15. Gate Y Activity Indicator LED

16. Gate X Activity Indicator LED

17. ProGraM Page Select; PGM 1

18. Return to Play, PGM 2: Hold to store settings.

19. Indicate Latch (Hold) or Indicate Active Program Page

20. Touch Grid: Flashes to indicate storage taking place.

9. Touch Grid sensitivity control.

To increase sensitivity, set the position 100% clockwise.

Sensitivity:

11. CV: An unquantized Control Voltage of the currently selected location will appear at this output. At

the CV OUT, the location potentiometers are always “live.” Value 0 to 4.5V

Advertising