© Copyright 2005-2007 TERIDIAN Semiconductor Corporation

Feature

Code

Size

8KB

16KB

32KB

Description

Wh equation 1

0.2KB

N N/opt

N/opt

Wh equation 2

0.2KB

N/opt N/opt N/opt

Frequency
register

0.1KB

N

Y

Y

Inhibited if freq > 70Hz or voltage is below the
threshold

Wh net metering

0.4KB

N

N/opt

Y

Used only for automatic calibration. No display is
provided.

Wh export register 0.25KB

N

N/opt N/opt

Wh

exported, display reads “3 999999”

Wh export pulse
output

0.25KB N N/opt N/opt

Wh exported, display reads “3 999999”

VARh register

0.1KB

N

N/opt

Y

For autocalibration, and power factor calculation,
signed (net metering).

VARh pulse
output

0.25KB N N/opt Y

VARh import
register

0.4KB N N/opt Y

VARh import
pulse output

0.25KB N N/opt Y

VARh export
register

0.4KB N N/opt Y

VARh export
pulse output

0.25KB N N/opt Y

Operating hours
register

0.36KB N N/opt N/opt

“5

99999.9” Nonvolatile count of tenths of hours of

powered operation since first cold start.

RCT time register 0.18KB

N/opt

Y

Y

RCT date register 0.21KB

N/opt

Y

Y

Pulse source
selection

0.4KB

N

N/opt

Y

This is the ability to route most calculated energy
values to a pulse output. The 8K code provides only
Wh pulses.

Dual IMAX
registers

0.2KB

Y

Y

Y

IMAX2 adjusts current, Wh and VARh from channel B
to same units as A. Creep thresholds are required,
but need not be adjusted when IMAX2 changes.

RMS current
register

0.2KB

N

N/opt

Y

Implemented for two phases “P”, 1 & 2 “1.P 000.000”

RMS voltage
register

0.2KB

N

N/opt

Y

Implemented for two phases “P”, 1 & 2 “1.P 000.000”

Power factor
register

0.3KB N N/opt N/opt

Two

phases are displayed with sign. Reset at reset

and the start of each minute. Volatile.

Table 5-6: Power Registers and Pulse Output Features