Tap controller block diagram, Tap electrical characteristics, Tap controller – Cypress CY7C1250V18 User Manual

Page 15

Advertising
background image

CY7C1246V18, CY7C1257V18
CY7C1248V18, CY7C1250V18

Document Number: 001-06348 Rev. *D

Page 15 of 27

TAP Controller Block Diagram

TAP Electrical Characteristics

Over the Operating Range

[10, 11, 12]

Parameter

Description

Test Conditions

Min

Max

Unit

V

OH1

Output HIGH Voltage

I

OH

=

−2.0 mA

1.4

V

V

OH2

Output HIGH Voltage

I

OH

=

−100 μA

1.6

V

V

OL1

Output LOW Voltage

I

OL

= 2.0 mA

0.4

V

V

OL2

Output LOW Voltage

I

OL

= 100

μA

0.2

V

V

IH

Input HIGH Voltage

0.65V

DD

V

DD

+ 0.3

V

V

IL

Input LOW Voltage

–0.3

0.35V

DD

V

I

X

Input and Output Load Current

GND

≤ V

I

≤ V

DD

−5

5

μA

0

0

1

2

.

.

29

30

31

Boundary Scan Register

Identification Register

0

1

2

.

.

.

.

108

0

1

2

Instruction Register

Bypass Register

Selection
Circuitry

Selection
Circuitry

TAP Controller

TDI

TDO

TCK

TMS

Notes

10. These characteristics apply to the TAP inputs (TMS, TCK, TDI and TDO). Parallel load levels are specified in

“Electrical Characteristics” on page 20

.

11. Overshoot: V

IH

(AC) < V

DDQ

+ 0.3V (pulse width less than t

CYC

/2). Undershoot: V

IL

(AC) >

0.3V (pulse width less than t

CYC

/2).

12. All voltage refers to ground.

[+] Feedback

[+] Feedback

Advertising
This manual is related to the following products: