Maximum ratings, Operating range, Electrical characteristics – Cypress CY7C1250V18 User Manual

Page 20: Dc electrical characteristics, Ac input requirements

Advertising
background image

CY7C1246V18, CY7C1257V18
CY7C1248V18, CY7C1250V18

Document Number: 001-06348 Rev. *D

Page 20 of 27

Maximum Ratings

Exceeding maximum ratings may impair the useful life of the
device. These user guidelines are not tested.

Storage Temperature ................................ –65°C to + 150°C

Ambient Temperature with Power Applied. –55°C to + 125°C

Supply Voltage on V

DD

Relative to GND .......–0.5V to + 2.9V

Supply Voltage on V

DDQ

Relative to GND ..... –0.5V to + V

DD

DC Applied to Outputs in High-Z ......... –0.5V to V

DDQ

+ 0.3V

DC Input Voltage

[11]

............................... –0.5V to V

DD

+ 0.3V

Current into Outputs (LOW)......................................... 20 mA

Static Discharge Voltage (MIL-STD-883, M 3015).... >2001V

Latch up Current..................................................... >200 mA

Operating Range

Range

Ambient

Temperature

V

DD

[15]

V

DDQ

[15]

Com’l

0°C to +70°C

1.8 ± 0.1V

1.4V to V

DD

Ind’l

–40°C to +85°C

Electrical Characteristics

Over the Operating Range

[12]

DC Electrical Characteristics

Parameter

Description

Test Conditions

Min

Typ

Max

Unit

V

DD

Power Supply Voltage

1.7

1.8

1.9

V

V

DDQ

IO Supply Voltage

1.4

1.5

V

DD

V

V

OH

Output HIGH Voltage

Note 16

V

DDQ

/2 – 0.12

V

DDQ

/2 + 0.12

V

V

OL

Output LOW Voltage

Note 17

V

DDQ

/2 – 0.12

V

DDQ

/2 + 0.12

V

V

OH(LOW)

Output HIGH Voltage

I

OH

= –0.1 mA, Nominal Impedance

V

DDQ

– 0.2

V

DDQ

V

V

OL(LOW)

Output LOW Voltage

I

OL

= 0.1 mA, Nominal Impedance

V

SS

0.2

V

V

IH

Input HIGH Voltage

V

REF

+ 0.1

V

DDQ

+ 0.15

V

V

IL

Input LOW Voltage

–0.15

V

REF

– 0.1

V

I

X

Input Leakage Current

GND

≤ V

I

≤ V

DDQ

–2

2

μA

I

OZ

Output Leakage Current

GND

≤ V

I

≤ V

DDQ,

Output Disabled

–2

2

μA

V

REF

Input Reference Voltage

[18]

Typical Value = 0.75V

0.68

0.75

0.95

V

I

DD

[19]

V

DD

Operating Supply

V

DD

= Max., I

OUT

= 0 mA,

f = f

MAX

= 1/t

CYC

300 MHz

1000

mA

333 MHz

1080

mA

375 MHz

1210

mA

I

SB1

Automatic Power Down
Current

Max. V

DD

,

Both Ports Deselected,
V

IN

≥ V

IH

or V

IN

≤ V

IL

f = f

MAX

= 1/t

CYC

,

Inputs Static

300 MHz

290

mA

333 MHz

300

mA

375 MHz

320

mA

AC Input Requirements

Over the Operating Range

[11]

Parameter

Description

Test Conditions

Min

Typ.

Max

Unit

V

IH

Input HIGH Voltage

V

REF

+ 0.2

V

DDQ

+ 0.24

V

V

IL

Input LOW Voltage

–0.24

V

REF

– 0.2

V

Notes

15. Power up: assumes a linear ramp from 0V to V

DD

(min) within 200 ms. During this time V

IH

< V

DD

and V

DDQ

< V

DD

.

16. Outputs are impedance controlled. I

OH

= –(V

DDQ

/2)/(RQ/5) for values of 175

Ω < RQ < 350Ω.

17. Outputs are impedance controlled. I

OL

= (V

DDQ

/2)/(RQ/5) for values of 175

Ω < RQ < 350Ω.

18. V

REF

(min) = 0.68V or 0.46V

DDQ

, whichever is larger. V

REF

(max) = 0.95V or 0.54V

DDQ

, whichever is smaller.

19. The operation current is calculated with 50% read cycle and 50% write cycle.