6159939020 SD25 Series Screwdrivers

Page 16

39-30-40409

The screwdriver inputs are software selectable using VS. To disable the push-to-start function, assign
the Cycle On input, Cycle Enable input and the Clear Outputs input to the Trigger. The typical inputs
for a screwdriver with push-to-start function disabled are shown below.

Enabling the Push-to-Start Function

Typically, to start a fastening cycle when the push-to-start function on a handheld screwdriver is
enabled:

Press the throttle/trigger lever to enable the fastening cycle.

Push down firmly on the screwdriver to start the fastening cycle.

Release the throttle/trigger lever to stop the fastening cycle.

OR

Release the pressure on the screwdriver to stop the fastening cycle.