Figure 22: Installed Roll Cylinder

In several cases, the lower cylinder

mount on the roll control hydraulic
cylinder has failed. In the
documented cases, the bracket has
failed at the weld shown in Figure 23.
It is recommended that all sprayers
with roll control add weld to the
existing bracket to prevent failure.

Some sprayers from 2005 and newer

already have gussets added at the
factory.

Figure 23: Roll Cylinder Mount Weld

Locations

Figure 24: Roll Cylinder Installed with

Hoses