3 wing sensor installation – NORAC UC4+BC+JD8 User Manual

Page 13

Advertising
background image

10

4.3 W

ING

S

ENSOR

I

NSTALLATION

1. Mount the Low Profile Sensor Mounting

Brackets (B20) onto the boom as show in
Figure 4 and Figure 5 with the mounting
base in front of the tube.

Figure 4: Low Profile Bracket Mounting

Figure 5: Low Profile Bracket Mounted on

Boom

If possible, mount the sensor

brackets while the booms are in their

folded position to ensure that they
will not interfere with anything when
the boom is folded for transport.

Mounting the sensor bracket to the

break-away section of the boom may
cause the boom to drop suddenly as
a break-away occurs. This will occur
on break-away sections which lift as
they break away.

For optimal boom tip protection, it is

recommended that the sensor be
mounted within approximately two
feet (60cm) of the boom tip.

Please refer to the UC4+ system warranty
at the end of the UC4+ Sprayer Boom
Control Operator’s Manual
(M01) for
implications.

2. Mount the NORAC UC4+ ultrasonic

sensors (E02) into the sensor brackets. The
sensors should be oriented forward (ahead)

of the boom.

When installing the UC4+ sensors

(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 9).

3. Sensor cables should run either through

hole in the back or through the side cut-out
and behind the bracket. Ensure the cable is

clear of moving parts and will not be
damaged during folding. Cable-tie the
connector in place. The cable must not hang
below the boom

Front