6 hydraulic installation, 1 valve assembly – NORAC UC4+BC+JD8 User Manual

Page 22

Advertising
background image

19

4.6 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very high
pressure. Before disconnecting any
hydraulic lines ensure all pressure has
been bled from the system.

IMPORTANT:

Component failure due to oil
contamination is not covered under the
UC4+ Spray Height Control system
warranty. It is recommended that a
qualified technician does the hydraulic
installation.

4.6.1 Valve Assembly

Orifices are not installed in the 1

st

and 2

nd

stations of the NORAC valve

block for this sprayer because the

John Deere orifices in the wing
cylinders are used.

1. On a clean surface remove all plastic plugs

from the NORAC hydraulic Valve block
(V01) (Figure 21).

2. Install the 6MB-6MOR fittings (F05) on the

"P" and "T" ports and tighten to 18 ft-lbs.

Figure 21: NORAC Valve Block

3. Install the 4MOR-4MB fittings (F06) into the

"S" port and tighten to 11 ft-lbs.

4. Install the 6MB-6MOR fittings (F05) into the

"A" and "B" ports and tighten to 18 ft-lbs.

5. Install the 6MBP (*F09) into the “A” port of

the 3

rd

station of the block.

6. Insert the orifice (*F08) into the “B” port of

the 3

rd

station of the block.

7. Install the 6MB 6MOR fitting (*F05) into the

“B” port of the 3

rd

station of the block.

If the Roll Control Option is also

being installed the 4

th

station valve

can be assembled before mounting
the valve. See the Roll Control
Option Installation Manual that came
with your kit.

8. Remove the plug from the Sense Line Bleed

port. Location is shown in Figure 22.
Gently tap the plug with a hammer to loosen
it before attempting to remove it. To access
bleed orifice, remove the valve coil that is
covering it, by unscrewing the nut on the
coil. Remove the Sense Line Bleed Orifice
and discard.

9. Install the setscrew (F11) into the Sense

Line Bleed Orifice location. Ensure the
setscrew is threaded entirely into the hole
and tightened to 35-40 in-lbs to ensure a
tight seal.

10. Reinstall the plug and tighten to 35-40 in-lbs.