2. Connect the 16-pin AMP plug on the

power cable (C10) to the UC4+
Control Panel (E01) in the sprayer cab.

3. Connect the Amp power cable (C14)

to the 3 pin AMP power cable on C10.
Cable C14 can be connected in line
with the Summers’ control box/joystick
power connection in the tractor cab

(Figure 22).

4. Route the longest connector on cable

C10 to the tractor hitch.

5. Connect the 16 pin AMP connector on

cable C11 to the 16 pin AMP connector
on C10 at the sprayer hitch.

Figure 23: Cable Configurations at Rear of Sprayer

6. Route cable C11 to the rear of the

sprayer, near the sprayer valve block.

7. Attach the valve cable C03 to the 6 pin

shroud on cable C11.

8. Attach cable C17 to the 3-pin shroud

and 6-pin tower on cable C11.

9. Connect cables C03 and C17 to the

NORAC valve block as shown in
Figure 24.

10. Connect the UC4 Roll cable C16 to the

three pin shroud on cable C17.

One connector on C17 will

remain disconnected. It is used
when installing other UC4+

options. Install P01 onto this
connector.

Figure 24: Valve Cable Connections