7. Disconnect the left and right raise lines from the Rogator valve block and insert the

6FORXR 6MORT tees (F02).

8. Connect the 90 degree ends of hoses H03 to the F02 tees and route the hoses to the

NORAC valve block.

9. Install the 6MOR 6FORX90 (F07) fitting onto fitting F06 on the left “B” port of the

NORAC valve block.

10. Install the 6MOR 6FORX45 (F09) fitting onto fitting F06 on the right “B” port of the

NORAC valve block.

11. Connect the straight end of the hose H03 from the left raise line to fitting F07.

12. Connect the straight end of the hose H03 from the right raise line to fitting F09.

13. The existing lower lines do not need to be modified. Leave these lines connected to the

Rogator valve block.

Figure 31: NORAC Valve Block Tilt Cylinder Plumbing

Figure 32: Right and Left Tilt Cylinder Plumbing at Rogator Valve Block

F09

F07

H03

H03

F02

F02

H03

F06

F08