12.5 Setup Messages

The following are descriptions of messages or problems that may be encountered during the
automatic setup or retune.

"Timeout":

This message may occur if the system is trying to move a boom but does not see any
change in the sensor heights. If the cylinder is fully extended or retracted, manually
reposition the boom into the middle of the stroke and resume the setup by holding the

button.

For left and right booms that do not adjust below the level of the main boom, ensure that
the main boom is within 125cm (50 inches) above ground before attempting an Install or
ReTune.

Ensure there is enough hydraulic pressure to move the boom.

"Mot’n Dly":

The system detects motion and is waiting for the boom to stop moving.

"Wiring!":

This message is shown at the wiring test if the system receives a signal from the wrong
sprayer switch. This will occur if the wiring is incorrect or there is a poor cable
connection. Pressing the wrong switch during this test will also display this error message.

"Too Many":

The system has detected too many sensors connected. Remove the additional sensors or
set up the system manually.

"Bakwards":

This message will be shown if the boom moves in the wrong direction of what is expected
by the UC4.5 system. This may be caused by a wiring or hydraulic problem. An extremely
under damped boom or high wind conditions may also cause this message to appear.

"TooHigh!" or "TooLow!":

The boom is positioned higher than 60 inches (150 cm) or lower than 30 inches (80 cm).
The system setup was likely started with the boom too high or too low. Restart the setup
with the boom positioned at 35 inches (90 cm).