POWER SUPPLY-MAINS

Connect the power cord as follows:

L (live) =brown
E (earth) =yellow/green
N (neutral) =blue

Use the plug provided to connect the mains power to the projector paying attention to the voltage and frequency marked
on the panel of the projector. It is recommended that each projector be supplied separately so that they may be
individually switched on and off.

IMPORTANT
It is essential that each projector is correctly earthed and the electrical installation conforms to all relevant
standards.

CONTROL CONNECTION

Connection between controller and projector and between one projector and another must be made with a 2
core-screened cable, with each core having at least a 0.5mm diameter. Connection to and from the projector is via
cannon 3 pin (which are included with the projector) or 5 pin XLR plugs and sockets. The XLR's are connected as shown
in the figure above.
Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each other. The body of
the plug is not connected in any way. The XL FRAMING 1200 accepts digital control signals in protocol DMX512 (1990).
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s output to the second fixture’s input
and connect the rest fixtures in the same way. Eventually connect the last fixture’s output to a DMX terminator as shown
in the figure below.

DMX OUT

DMX IN

DMX IN FROM

TERMINATER

DMX IN

DMX OUT

DMX IN

DMX OUT

CONTROLLER

Advertising