Ac test loads and waveforms – Cypress CYV15G0404DXB User Manual

Page 27

Advertising
background image

CYV15G0404DXB

Document #: 38-02097 Rev. *B

Page 27 of 44

Differential CML Serial Outputs: OUTA1

±, OUTA2±, OUTB1±, OUTB2±, OUTC1±, OUTC2±, OUTD1±, OUTD2±

V

OHC

Output HIGH Voltage
(V

cc

Referenced)

100

Ω differential load

V

CC

– 0.5

V

CC

– 0.2

V

150

Ω differential load

V

CC

– 0.5

V

CC

– 0.2

V

V

OLC

Output LOW Voltage
(V

CC

Referenced)

100

Ω differential load

V

CC

– 1.4

V

CC

– 0.7

V

150

Ω differential load

V

CC

– 1.4

V

CC

– 0.7

V

V

ODIF

Output Differential Voltage
|(OUT+)

− (OUT−)|

100

Ω differential load

450

900

mV

150

Ω differential load

560

1000

mV

Differential Serial Line Receiver Inputs: INA1

±, INA2±, INB1±, INB2±, INC1±, INC2±, IND1±, IND2±

V

DIFFs

[13]

Input Differential Voltage |(IN+)

− (IN−)|

100

1200

mV

V

IHE

Highest Input HIGH Voltage

V

CC

V

V

ILE

Lowest Input LOW Voltage

V

CC

– 2.0

V

I

IHE

Input HIGH Current

V

IN

= V

IHE

Max.

1350

μA

I

ILE

Input LOW Current

V

IN

= V

ILE

Min.

–700

μA

VI

COM

[15]

Common Mode input range

((V

CC

– 2.0V) + 0.5)min,

(V

CC

– 0.5V) max.

+1.25

+3.1

V

Power Supply

Typ.

Max.

I

CC

[16, 17]

Max Power Supply Current

REFCLKx =
MAX

Commercial

910

1270

mA

Industrial

1320

mA

I

CC

[16, 17]

Typical Power Supply Current

REFCLKx =
125 MHz

Commercial

900

1270

mA

Industrial

1320

mA

CYV15G0404DXB DC Electrical Characteristics

(continued)

Parameter

Description

Test Conditions

Min.

Max.

Unit

AC Test Loads and Waveforms

Notes

15. The common mode range defines the allowable range of INPUT+ and INPUT- when INPUT+ = INPUT-. This marks the zero-crossing between the true and

complement inputs as the signal switches between a logic-1 and a logic-0.

16. Maximum ICC is measured with VCC = MAX, RFENx = 0,TA = 25°C, with all channels and Serial Line Drivers enabled, sending a continuous alternating 01

pattern, and outputs unloaded.

17. Typical ICC is measured under similar conditions except with VCC = 3.3V, TA = 25°C, RFENx = 0, with all channels enabled and one Serial Line Driver per

transmit channel sending a continuous alternating 01 pattern. The redundant outputs on each channel are powered down and the parallel outputs are unloaded.

18. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.
19. The LVTTL switching threshold is 1.4V. All timing references are made relative to where the signal edges cross the threshold voltage.

2.0V

0.8V

GND

2.0V

0.8V

80%

20%

80%

20%

R

L

(Includes fixture and
probe capacitance)

3.0V

V

th

= 1.4V

≤ 270 ps

≤ 270 ps

[19]

V

th

= 1.4V

3.3V

R1

R2

R1 = 590

Ω

R2 = 435

Ω

(Includes fixture and
probe capacitance)

C

L

≤ 7 pF

(a) LVTTL Output Test Load

R

L

= 100

Ω

(b) CML Output Test Load

C

L

(c) LVTTL Input Test Waveform

(d) CML/LVPECL Input Test Waveform

≤ 1 ns

≤ 1 ns

V

IHE

V

ILE

V

IHE

V

ILE

[18]

[18]

[+] Feedback

[+] Feedback

Advertising