Operation – CMA Dishmachines CMA-180UC User Manual

Page 18

Advertising
background image

Operation

PROBLEM LIKELY

CAUSE

SOLUTION

Start switch requires > 1
second activation to run
cycle

Defective (Instant Start) ice cube
relay

Replace ice cube relay

P/N: 00631.00

Defective drain/fill switch

Replace drain/fill switch

P/N: 15522.00

Activating fill switch does
not fill machine

Defective water solenoid valve

Replace water solenoid valve

P/N: 03603.10

Defective water solenoid valve

Replace water solenoid valve

P/N: 03603.10

Defective drain/fill switch

Replace drain/fill switch

P/N: 15522.00

Defective timer assembly

Replace timer assembly*

P/N: 14408.80

Fill (rinse water) won’t shut
off

Defective (Rinse Relay) ice cube
relay

Replace ice cube relay

P/N: 00631.00

Drain hose is kinked

Un-kink drain hose

Defective drain/fill switch

Replace drain/fill switch

P/N: 15522.00

Activating drain switch
does not drain machine

Defective drain valve

Replace drain valve

P/N: 04103.00

Cycle light does not light
while cycle runs

Defective cycle light

Replace cycle light (green)

P/N: 00406.60

Power light does not light
but machine runs

Defective power light

Replace power light (red)

P/N: 00406.00

Wash tank or final rinse
temperature does not
display

Defective digital thermometer

Replace digital thermometer

P/N: 03202.45

Both the wash tank
temperature and the final
rinse temperature do not
display

Defective thermometer
transformer

Replace thermometer
transformer

P/N: 03202.60

Defective digital thermometer

Replace digital thermometer

P/N: 03202.45

Wash tank or final rinse
displays wrong
temperature

Defective thermister

Replace thermister

P/N: 03202.65

*The timer assembly motor (

P/N: 00501.00

) or micro switches (

P/N: 00411.00

) can be replaced

independently if that’s the only component that’s failed.

MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13

Page

17

Advertising