Optional drain pump—installation instructions, Ptional, Rain – CMA Dishmachines CMA-180UC User Manual

Page 21: Nstallation, Nstructions, Parts manual 4.3. optional drain pump—i

Advertising
background image

Parts Manual

4.3.

Optional Drain Pump—I

NSTALLATION

I

NSTRUCTIONS

1. Start by removing the existing drain hose from the Drain Valve as shown in

Figure 1

.

From Scrap Tray

Remove

From Wash Tank

Figure 1

2. Locate the white and purple wires that are safe-ended and tie-wrapped at the top of the Drain

Pump compartment. Bring these wires out so they can be connected after mounting the Drain
Pump.

3.

Connect the 3-inch long pump inlet drain hose to the Drain Valve and mount the Drain Pump
using the nuts and washers provided with the kit as shown in

Figure 2

.

Remove this cover to
make wire connections.

Figure 2

4.

Remove the terminal cover and connect the white and purple wires to the two white wires
from the pump. Replace the cover.

White wire

Purple wire

Tighten this

hose clamp

over Drain

Valve.

Drain hose must elevate
12 to 16 inches before
dropping to drain.

3-inch pump

inlet drain

hose.

MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13