Culligan H-30 User Manual

Page 13

Advertising
background image

10

1. Locate the system’s supply valve and turn off the system’s water supply.

2. Open the dispenser faucet and drain the storage tank.

3. Place the filter assembly in a dish pan or similar container to catch any

dripping water.

4. Relieve the pressure in the system by loosening the threaded tubing

connector at the bottom of the RO membrane filter housing. Retighten

the fitting.

5. Pull the u-clip from the top of the particle prefilter housing. (Fig. 4)

6. Push the top cap into the housing to free the o-ring seal, then pull the

top cap from the housing.

7. Remove the particle prefilter element from the housing and discard.

8. Clean the inside of the housing and top cap.

9. Lubricate the new particle prefilter cartridge o-ring with water and

insert the new filter cartridge into the top cap. Note: If Model H-30S-R,

do not install particulate/carbon filter at this time.

10.Pour two tablespoons liquid chlorine bleach or 3 ounces hydrogen

peroxide into the particle prefilter housing.

11.Assemble the housing, the top cap and the u-clip.

12.Repeat steps 5-8 and remove the activated carbon cartridge and, if

using chlorine bleach, the RO membrane filter.

NOTICE:

If the RO membrane filter is to be reused, place it in a new

plastic bag to keep it clean.

13.Assemble the empty housings and replace the u-clips. Make sure all

tubing is connected properly.

14.Turn on the supply valve and allow the system to fill with water. Once

water begins to drip or flow from the faucet, close the faucet and allow

the tank to fill.

15.Turn off the supply valve and allow the system to sit for ten minutes.

16.Open the dispenser faucet and drain the storage tank.

17.Repeat steps 4, 5, 6, 9, and 11 for replacement of the activated carbon,

particulate/activated carbon (Model H-30S-R) and RO membrane filter

cartridges.

18.If using hydrogen peroxide, disconnect the storage tank tube from the

tubing tee. With an eyedropper or similar device, inject one tablespoon

of hydrogen peroxide into the tube and reconnect it to the tee.

19.Note the direction of flow and disconnect the tubing from the

polishing filter. Fig. 5.

20.Note the direction of flow and install the new polishing filter.

21.Replace the filter assembly into its mounting location.

22.Repeat step 14.

23.After the storage tank has filled (3-4 hours), open the faucet and drain

the storage tank to flush the new polishing filter and any remaining

sanitizing solution from the system.

24.Allow the system to refill. Your system is now ready for use.

25.Record your service on the chart at the end of this booklet.