Installation, Application guidelines, Table 1 – Culligan H-30 User Manual

Page 8

Advertising
background image

INSTALLATION

This Owner’s Guide provides visual assembly reference only. Since specialized

skills are required in the assembly of the drinking water system, we recom-

mend that you contact your local independently operated Culligan dealer to

complete this installation.

APPLICATION GUIDELINES

The Good Water Machine

is designed for use on potable water supplies

meeting the guidelines outlined in Table 1. The system should be installed on

your home’s cold water line. The flushing stream should discharge through

an approved siphon break as illustrated in Figure 1. Installation of this system

must comply with state and local laws and regulations.

5

TABLE 1

Influent Water Characteristic

Pressure

40 - 120 psi (280 - 827 kPa)

Temperature

33 - 100°F (1 - 38°C)

Total Dissolved Solids (TDS)

1

0 - 4000 ppm ( 0 - 4000 mg/L)

pH

5 - 10

Chlorine

2

0 - 3 ppm ( 0 - 3 mg/L)

Chloramine

0 - 3 ppm ( 0 - 3 mg/L)

Turbidity

0 - 10 NTU

Iron

0 - 1 ppm (0 - 1 mg/L)

Bacterial Quality

Potable

1

See the Technical Manual for all applications where TDS exceeds 1000 ppm (1000 mg/L).

A booster pump is strongly recommended.

2

The reverse osmosis membrane filter used in this system may be damaged by chlorine.

This system includes activated carbon which protects this element by reducing chlorine.

Influent chlorine should not exceed 3 mg/L.

Advertising