8

Screw

6-32 X 1"

(2)

Screw

6-32 X

3

/

8

"

(2)

Wood

Screw

1" (2)

Drywall

Anchor

6-32 (2)

12v Battery

W-72

Control

W-72

Control Holder

VERSA•TOUCH2® COnTROl InSTAllATIOn

COnTROl BRACkET InSTAllATIOn

Standard Light Switch

Step A. Remove the two screws holding the switch
cover plate. Do not remove the cover plate.

Step B. Orient the control bracket as shown and line
up the two inner mounting holes with those on the
switch.

Step C. Insert and tighten the screws using the
provided screwdriver.

INNER

mOUNTINg

HOLES

CONTROL
bRACKET

STANDARD

TOggLE

SWITCH

SWITCH

COVER

pLATE

Rocker Light Switch

Step A. Break off the two tabs by pushing outward.

Step B. Remove the two screws holding the switch
cover plate. Do not remove the cover plate.

Step C. Orient the control bracket as shown and line
up the two inner mounting holes with those on the
switch.

Step D. Insert and tighten the screws using the
provided screwdriver.

OUTER

mOUNTINg

HOLES

CONTROL
bRACKET

ROCKER

LIgHT

SWITCH

SWITCH

COVER

pLATE

Wall Installation

Step A. Locate a 2x4
wall stud in a convenient
location.

Step B. Orient the control
bracket as shown over
the 2x4 stud.

Step C. Insert the 1" wood
screws in either the inner
or outer mounting holes
and tighten using the
provided screwdriver.

DECOR OVALHEAD SCREW

6-32 x 1"

ANCHOR

pANHEAD

SCREW

DRyWALL ANCHOR

NOTE: The wall anchors and 6-32 x 1" screws may
be used in situations where mounting to a stud is
not possible. Use the inner mounting holes. After
securing the anchor, discard the anchor’s pointed
screws and use the 6-32 decor ovalhead screws
supplied.

WOOD

SCREW 1"

Versa•Touch2™ hardware (not to scale)

Step 17. Follow instructions for the type of transmitter control bracket you will be using.

SAFETY FIRST: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/

switch. CAUTION! Do not use with wall dimmer.

warNING: To reduce the risk of fire or electric shock, do not use this fan with any solid state speed control

device. Use only the control provided with this fan.