Aerobic power measurement (1) – CatEye EC-37OO User Manual

Page 17

Advertising
background image

24

TIME

PLL

WT

AGE

lb

TEST

TIME

kg·m

TM

min:sec

watt

kg·m

rpm

TEST

TIME

kg·m

TM

min:sec

watt

kg·m

rpm

TEST

Aerobic power measurement (1)

• Input your age, pulse limit, weight and sex. The initial display

prior to input is as in the drawing. The numeric for age is blink-
ing.

Initial

Value

Setting Range

Age

40

10~ 99

Pulse Limit

160 bpm

80~ 200 bpm

Weight

130 lb

Sex

Male

• The pitch sound to adjust your cadence at 60 rpm (rings every

half second) is set "ON".

• There is no graphic display yet in the LCD.

• Press the

MODE

button to change the blinking numeric.

• You can increase or decrease the blinking numeric by pressing

the

button.

Select the Aerobic Power
Measurement Program

1

2

Input Conditions

• For program selection see the Starting up section page 18.

Start Program

3

• After setting your conditions, adapt the earlobe pulse sensor

and press

ADV

button to start program.

• After printing out the conditions the LCD changes as in the

drawing.

• The word "READY" will be displayed on LCD panel. Wait still

for one minute.

• After one minute has elapsed, the buzzer sounds and the pitch

sound begins. Then start pedaling according to the pitch sound.

Note: You can cancel the pitch sound by pressing

the

button. If the symbol is on the LCD, the pitch

sound is ON, and if not pitch sound is OFF. Pressing the
pitch sound button toggles ON/OFF.

• The initial workload (pedal torque) is indicated in blinking dot

in the graphic section of the LCD. One dot along the horizontal
axis indicates 30 seconds, and one along the vertical axis 0.5
kg·m. At every 30 seconds, the row of dots will increase by one
towards the right of the graphic display, with the last row blink-
ing.

• At the 4th and 7th minutes the pedal torque will increase de-

pending on your pulse rate at that time. The increased torque of
2nd and 3rd stages will be indicated in dots time after time in the
graphic part.

25

• The buzzer sounds ten minutes later and the test result is dis-

played on the LCD, and also printed out. The program then
enters the 5 minute cool down phase and the

COOL

symbol

lights up, however the LCD still displays the test result. Only
the calorie consumption data on LCD panel will be updated if
you keep pedaling.

Note: When the upper pulse limit alarm is activated

If the upper pulse limit alarm is activated while the elapsed
time is within 4 minutes, making the buzzer beep and drop-
ping the resistance to the minimum of 0.5 kg·m, the test
result is not displayed. If the upper pulse limit alarm is acti-
vated after the elapsed time exceeds 4 minutes, the result is
displayed based on the progress up to that point. In this
case the result is distinguished from normal results by add-
ing "=" to the printing data of the printer.

TIME

COOL

MOU

EC

PWC

PFL

ml/kg·min

kcal

watt

kg·m

TEST

Sample print out

Test Result Display,
Cool Down

4

• Shows that the Aerobic Power Measurement program has

been performed.

• Date of execution
• Name: Put down your name in the blank.
• Sex : M = Male, F = Female
• Age
• Weight (lb or kg)
• Upper limit pulse rate
• Elapsed time (minute): printed every 30 seconds
• Cadence
• Work rate (watt)
• Pulse rate
• Pulse rate chart
• One minute before exercise: shows the pulse rate at the rest.

• 1st stage

• 2nd stage

• 3rd stage

• Calorie consumption
• Maximum physical capacity (PWCmax): the greater, the

better.

• Maximum Oxygen uptake (MOU): the greater, the better.
• 5 rank physical fitness level

End Program

5

.

.

• If the 5 minute cool down phase elapses or if you press

the

ADV

button, the buzzer sounds and the program ends.

• The LCD returns to the initial screen.

• If you are completely finishing the exercise, be sure to turn the

power off by the switch at the right side of the main unit.