For technical questions, please call 1-800-444-3353.

SKU 90599

3.

do not wire multiple panels in

series. If you need to connect two

or more solar panels together, this

work must be done by a qualified

electrician unless they are connected

through a regulator.

4. This solar panel kit is not designed

for tie-in to a grid. Only a licensed

electrician and a licensed building

contractor can safely design and

implement a grid tie-in system. Any

grid tie-in system must meet all

applicable building and electrical

codes, and must meet standards

established by the area power

company. Improper grid tie-in can

result in electrocution, fire, and other

serious personal injury and property

damage. An incorrectly installed grid

tie-in system can cause feedback

voltage, resulting in electrocution of

electrical utility workers.

5.

do not stand on or otherwise apply

pressure to panel.

6.

handle solar panel with care,

edges may be sharp.

7.

do not focus light on panel.

8.

Install components with enough

space to allow proper cooling.

9.

This product may occasionally

produce more current and/or

voltage than its rated output.

Increase output ratings by 25%

when determining component

required voltage and amperage

ratings. Refer to Section 690-8 of

the National Electrical Code for an

additional multiplying factor of 125

percent (80 percent derating) which

may apply.

10. Panel must be connected using

UL listed outdoor rated wire of the

correct thickness (gauge) for the

amperage rating and length (see

warning number 9 also). Follow the

guidelines in the chart below:

current

in Amps

Maximum Length

5'

10' 15'

20' 25'

0-5

18

6-7

18

16

8

18

16

10

18

16

11-12

16

14

15

14

12

18

18

16

20

14

12

10

22-24

12

30

16

14

10

40

12

10

8

50

14

100

12

10

6

4

150

10

8

4

2

200

8

6

Minimum Wire Gauge

11. Install an appropriate charge

controller/regulator to regulate output

and prevent damage. Do not attach

panel to battery or power grid without

proper regulator, inverter, and/or

charge controller.

12. Install and use according to

applicable National Electrical Code

(NEC) standards.

13. This panel is not rated for use as

fire-resistant roofing. If installing on

a roof, install only over a fire resistant

roof covering rated for the application.

14. Verify that installation surface has no

hidden utility lines before drilling or

driving screws.

15. Install only according to these

instructions. Improper installation

can create hazards.