INSTALLATION REQUIREMENTS/ SPECIFICATIONS

2-5

POWER SUPPLY REQUIREMENTS

Parameter

Typical

Worst

Value

Case

120V Input Voltage: 120 V

90 to 130 V

Input Current

NB20E:

0.5 Amps

1.0 Amps

NB25E:

0.75 Amps

1.5 Amps

Frequency Range:

47 - 63 Hz

220V Input Voltage:

220 V

180 to 264 V

Input Current

NB20E:

0.25 Amps

0.5 Amps

NB25E:

0.375 Amps

0.75 Amps

Frequency Range:

47 - 63 Hz

Overload Protection

Input:

(2) 3AG 3 amp fuses in series with both primary
inputs.

Output:

(2) 3AG 1 amp fuse for each AUI port.

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:

+5

°

to +40

°

C

Non-operating Temperature: -30

°

to +90

°

C

Operating Humidity:

5 to 95% (non-condensing)