PRG LIGHTING SYSTEMS NETWORKING GUIDE

5

ON

SERIES 400

400A DISCONNECT

OFF

CAT5 WIRE TO

LOCAL RACKS

SWITCH

FROM REMOTE RACKS

FIBER OPTIC CABLE

TO REMOTE RACKS

FIBER OPTIC CABLE

15A/30A "MIXED"

BREAKOUT BOX (A)

DEVICE

15A

15A

DEVICE

NODE PLUS

VIRTUOSO

TRUNK CABLE

PRIMARY

FRONT OF HOUSE

BREAKOUT MODULE

ETHERNET SWITCH

DMX512 UNIVERSE 2

DMX512 UNIVERSE 1
DMX512 UNIVERSE 2

DMX OVER ETHERNET

DEVICE A

INTERCOM

FOH A/B

A

B

SERIES 400 RACK

15A/30A "MIXED"

BREAKOUT BOX (B)

30A

DEVICE

30A

DEVICE

DEVICE

DEVICE

DEVICE

DEVICE

15A

30A

15A

30A

DMX OVER ETHERNET
DMX512 UNIVERSE 1

(A)

(B)

(A)

(B)

6X DMX

BREAKER

MODULE 6

BREAKER

MODULE 5

MODULE 4

BREAKER

MODULE 1

FOH

BREAKER

CONTROL CONSOLE

BACKUP

POWER IN

CONTROL CONSOLE

BREAKOUT MODULE

FRONT OF HOUSE

PRG Series 400 Distribution Rack

The PRG Series 400® Data and Power Distribution Rack offers significant
features, both standard and superior to other power distribution systems.

The Series 400 system consists of a Rolling Rack unit, up to six 3U Breaker
Modules, and associated Breakout Boxes connected by Trunk Cables. The
rack is designed to distribute house power service and control signals for
the purpose of operating automated luminaires or other remote devices up
to 500 feet away.

Optional components include the Front of House (FOH) Breaker and
Breakout Modules, which provides a convenient method of connecting
consoles and accessories at the mix riser position. The FOH Breaker
Module sources two sets of six 15-Amp circuits of AC line power and
provides system control data inputs for up to 10 USITT DMX512 universes
along with inputs for two 10/100BaseT Ethernet signals at the associated
FOH Breakout Module. The FOH A/B Switch is connected to the FOH
Breakout Module and can be used to input and track multiple DMX512
universes.

Series 400 Rack features:

+

Supports up to 72, 1.2k Watt Devices

+

Single, Dual, and 3-Phase Outputs

+

400 Amp Cam-Loks In and Out

+

120V and 208V Outputs

+

Digital Current and Voltage Metering

+

Safety Interlock with Breakout Boxes

+

System Master Switch

+

Front Panel Flush Rocker Circuit Breakers

+

Hot-Swappable Breaker Modules

+

10/100BaseT Ethernet and DMX512 Inputs

+

Signal Routing Control and Display

+

Rear 120V Convenience Outlets

+

L6-20 and Neutrik® 208V Outputs (on back of Rack)

+

Front and Back LED Lighting

+

3U of additional rack space for adding third-party signal processing
devices

+

Modular Design

+

Weighs a maximum of 305 lbs. when fully loaded

Note: Each Series 400 Rack requires a 400 Amp Disconnect. Refer to

"400 Amp Disconnect"

on page 8.

WARNING:

The Series 400 Rack utilizes high voltage power. Use

proper precautions when installing or servicing!

Sample Rack Configuration Diagram

(15/30A Mixed Breaker Modules and Front of House Components)