Art-net (series 400) mode, Merge options – PRG Node Plus User Manual

Page 20

Advertising
background image

18

PRG NODE PLUS USER MANUAL

Art-Net (Series 400) Mode

When the Node Plus has been loaded with Series 400 software, the menu system will provide "Series 400" screens
which can be used to set up and monitor the Art-Net system.

Setup

The "Series 400 Setup" screen is used to configure the Art-Net universes,
display options, and merge setting.

+

Universes - Specify the Art-Net universes (A-N) to be received and
translated (such as 000, 001, 002, 003, etc.).

+

Display - Specify whether the universes should be displayed as
numeric, alpha, or hex.

+

Merge - Specify a merge setting (2-Way, 3-Way, 4-Way) or "no
merge."

See below for details.

Status

The Address, DMX Monitor, and Network Stat screens provide status
feedback for the Art-Net system. These screens are not editable.

+

Address Screen - Shows the current system source (

a

,

b

, or

c

), active

universes, and thumbwheel address. (The thumbwheel address is for
ID purposes only).

+

DMX Monitor Screen - Shows the data for each active universe.
Press the menu toggle switch to cycle through all six ports.

+

Network Stats Screen - Shows transmit and receive statistics since
power-up.

TX #: successful transmits

fail: transmit failures

T/O: transmit time-outs

HwEr: transmit hardware errors

Mem: transmit memory errors

Apn: transmit buffer errors

RX #: successful receives

HwEr: receive hardware errors

Flag: receive invalid flag error

Cksm: receive checksum error

Buf: receive buffer shortage

Msg: receive message item shortage

Information

The Information screen displays software version date/time, verification of
valid Boot module, and programmed Network ID.

This screen is not editable.

Merge Options

The merge options available on the "Series 400 Setup" screen allow
merging of data for multiple universes assigned to the same number. For
example, if two inputs are set to 001a and 2-way merge is enabled, then
the resulting output for outputs set to universe 001 would be the highest
value for each channel between the two inputs (HTP). If three inputs are
active at 001, the outputs would be disabled.

Options are as follows:

+

noMerge: no universe merging.
(This is the default setting: noMerge = 1.)

+

2-Way: allows up to 2 universe inputs per universe.

+

3-Way: allows up to 3 universe inputs per universe.

+

4-Way: allows up to 4 universe inputs per universe.

Series 400 Setup

000 001 002 003 004 005

numeric noMerge

Addr

Setup

DmxMon

a

Series 400 Node

000 001 002 003 -- --

Info

Addr

Setup

a

001

DMX Port 1 (000)

001: 000 127 255 127 255
006: 000 000 000 000 000
011: 000 000 000 000 000
016: 000 000 000 000 000

Setup

DmxMon

NetSta

a

Network Stats

TX # 467

fail

0

T/O 0

HwEr 0

Mem 0

Apn 0

RX # 1262

HwER

0

Flag 0

Cksm 0

Buf 0

Msg 0

DmxMon

NetSta

Info

a

Information

Vers: 05/07/10 16:00

Boot: OK

NetId 00C0 5E02 048B

NetSta

Info

Addr

a

When used with the Series 400 rack, the
Node will follow the selected A, B, or C
system. The current system source is
displayed in the top corner of each S400
menu screen. System "a" is the default
system source for Art-Net configurations.