(See Picture B)

Caution: If you break off a tab and do not

remove it, this may stop the contactor from working and allow

240 volts into the RV.

10. Secure cable ends by tightening down strain reliefs over the input

and output wires. Do not over tighten as this could bite through

the insulation and cause a short.

11. Set time delay jumper on the circuit board. The factory setting is

for 15 seconds. Remove jumper to set for 136 seconds (02:16).

See Features Section on time delay to determine which to use.
(See Picture B)

12. Plug in display. (See Picture C)

13. Attach EMS lid with the six black machine screws provided.

14. Mount the EMS control box.

15. Installation is complete. Next, plug in and follow operating

instructions.

Installation After Transfer Box for

Protection from both Generator and AC Power.

For installation, in addition to the EMS Kit, you will need:

6 mounting screws

In some cases you will need a jumper cable, length to be

determined based on the placement of the EMS

Always use #6 wire.

1. Unplug RV from the AC power and be sure generator is off.

2. Locate transfer switch box; determine where the EMS control box

will be mounted.

3. Measure the distance between the transfer switch and the control

box and add one (1) foot. This is the length of cable that will be

required for the installation. Make sure 6-gauge, 4-conductor

cables are used.

4. Remove lid from transfer box, disconnect and remove the output

cable.

5. Take jumper cable and strip back one end three (3) inches, and the

other end the same as the end removed from the transfer box. The

cable removed from the transfer box must have at least three (3)

inches of the outer insulation removed. (See Picture A)

Advertising