1 control locations 3.2 heater rating plate, 3 service procedures – Reznor CAUA Users Manual User Manual

Page 7

Advertising
background image

Form O-CAUA, P/N 164772 R7, Page 7

.74

1.275

7/16

.125 ±.015 Spark Gap

5/32

Time

Delay

Relay

Ignition Control

Module

(Circuit Board)

Terminal Strip

Relay

Contactor

or Starter

Thermostat

Terminal

Strip

Pressure

Switch

Transformer

FIGURE 4 - Control

Locations in the

Electrical Compartment

(Remove the control

compartment access

panel)

3.1 Control

Locations

3.2 Heater Rating

Plate

The heater rating plate is a quick reference for information about a heater and its instal-

lation requirements. In addition, the Serial No. on the rating plate identifies components

used in manufacturing that specific heater. The serial number is coded to identify the

gas valve and ignition type that was installed on the heater at the time of manufacture.

This information is required if service and/or replacement parts are required.

Follow the example below to decode the heater Serial No.

Example: Heater Serial No. BIC78Q3N12345

BIC

78

Q3 N

12345

Month and Year

Safety Pilot Code

Type of Type of Consecutive

of Manufacture

(Type of Ignition)

Valve

Gas*

Number

* N = Natural Gas; L = Propane Gas

NOTE: In addition to the

rating plate, each heater

has a "Replacement

Parts Label" attached that

identifies parts specific to

that heater, as well as the

Model and Serial No. of the

heater.

3.3.1 Operating Gas Valve

Function: The gas valve automatically controls the gas flow to the main burners and

regulates the gas pressure.
Service: The valve has no field-repairable parts. Carefully remove external dirt accu-

mulation from the valve and check wiring connections.
Refer to Form I-CAUA, Paragraph 6.1, for instructions on checking manifold pressure.
The gas valve must be checked annually to ensure that the valve is shutting off gas

flow completely; see Maintenance Paragraph 2.2.3.

Gas

Valve

3.3.2 Ignition System

Function: The heater is equipped with a direct-spark integrated control system. The

system monitors the safety devices and controls the operation of the blower and venter

motors and the gas valve.

Control Module: The control module is an integrated board located in the control com-

partment. Supply and control wiring connects into the control module. The module has

an LED troubleshooting light which identifies operating problems. The control module

also acts as a fan control energizing the fan 30 seconds after ignition and delaying fan

shutdown for 160 seconds after the gas valve closes. See

FIGURE 6, page 8, for LED

codes and fan delay dip switch settings.

IMPORTANT: The serial number code can only identify the original equipment. Before servicing, check for a gas conver-

sion label. When inquiring about replacement parts, always provide the complete Model No. and Serial No.

To service this heater, it is necessary to understand the normal operating functions of

the heater controls. Refer to

FIGURE 4 to identify and locate the controls.

Ignitor

FIGURE 5 -

Spark Gap

Front View

of Ignitor

showing

Spark Gap

Measurement

Ignitor: The ignitor is located on the right

side of the burner assembly. Instructions

for cleaning and checking the ignitor are

included in the Paragraph 2.2.5. The spark

gap shown inches in

FIGURE 5 must be

maintained.

Flame Sensor: The flame sensor is located

on the left side of the burner assembly.

Instructions for cleaning and checking the

flame sensor are in Paragraph 2.2.5.

NOTE: This control is on

units manufactured begin-

ning 3/09. To replace an

ignition controller on a unit

manufactured prior to 3/09,

order kit

P/N 258251.