ROGUE TERRAIN OFF GRID POWER SUPPLY ENCLOSURE

INSTALLATION
The Rogue Terrain enclosure may be wall mounted or pole mounted .
If wall mounted the device shall be secured to the wall utilizing appropriate

customer-provided mounting apparatus .
If pole mounted, the slots in the flanges at the top and bottom of the enclosure

will accommodate a variety of sizes of U-bolts that may be used with a round

pole .

EXTERNAL POWER WIRING
Ensure that the Battery, Solar and Load fuses are removed from the

corresponding three black DIN mounted fuseholders .
External battery, solar and load wiring should use, at minimum, AWG 14

stranded copper wire and industry convention would dictate that all external

positive wiring should be red and negative (ground) wiring should be black .
Extend red and black wires from solar panel(s) into the rear cable grip at the

bottom of the enclosure and terminate on the designated Solar (+) and Solar

(-) terminals as identified on the wiring diagram on the inside cover of the

enclosure . Wire ends should be stripped at 3/8 inch . Terminal screws should

be tightened securely using the screwdriver provided on the inside cover of

the enclosure .
Extend red and black wires from the load into the front cable grip at the

bottom of the enclosure and terminate on the designated Load (+) and Load

(-) terminals as identified on the wiring diagram on the inside cover of the

enclosure . Wire ends should be stripped at 3/8 inch . Terminal screws should

be tightened securely using the screwdriver provided on the inside cover of

the enclosure .
If an internal battery is to be utilized, open the buckle on the web retaining

strap and set the battery at the bottom of the enclosure with the terminals

nearest the right end of the battery . Secure the battery with the web strap

and buckle, adjusting the buckle to hold the battery tightly in place . Connect

the red and black connectorized battery leads to the spade connectors on the

battery .
If an external battery is to be used, extend red and black wires from the battery

into the center cable grip at the bottom of the enclosure . Disconnect the

existing short connectorized red and black battery leads from the Battery

(+) and Battery (-) terminals as identified on the wiring diagram on the

inside cover of the enclosure and connect the external battery wiring to the

corresponding terminals . Wire ends should be stripped at 3/8 inch . Terminal

screws should be tightened securely using the screwdriver provided on the

inside cover of the enclosure .