3.4 Calibration Procedures

3.4.1

SA 3

1.

With the SA 3/SA3 3L removed from the enclosure, connect the mating connector.

2.

Apply power to the SA 3/SA3 3L by activating the system which is being annunciated

by the SA 3/SA3 3L.

3..

With the annunciator dimming switch in the bright position, adjust R9 to the desired

brightness.

4.

Place the annunciator dimming switch in the dim or low position, and adjust R8 to the

desired brightness.

5.

Press the annunciator test button and ensure that all annunciators illuminate to their

maximum adjusted brightness.

R8 Dim Adujust

R9 Bright Adjust

Figure 3-13

SA 3 / SA 3LAdjustment Locations