Sandia Aerospace SA 3NVG User Manual

Page 9

Advertising
background image

SR 34, SR 54, SR 64

Environmental Qualification Form

Page 8

NOMENCLATURE: MARC70 RELAY

TYPE/MODEL/PART NO: MARC70/SR34, SR54, SR64

TSO NUMBER: DO160Env. Cat.[A1D1]-CA9MN0XXXXXXZBABATZXXX

MANUFACTURER’S SPECIFICATION AND/OR OTHER APPLICABLE SPECIFICATIONS:

MARC70 INSTALLATION MANUAL 305147-00

MANUFACTURER: SANDIA AEROSPACE

ADDRESS: 3700 OSUNA RD NE, STE 711, ALBUQUERQUE, NM 87109

CONDITION

SECTION

DESCRIPTION OF TESTS CONDUCTED

Temperature and Altitude

Low Temperature

High Temperature

In-flight Loss of Cooling

Altitude

Decompression

Overpressure

4.0

4.5.1

4.5.2 & 4.5.3

4.54

4.6.1

4.6.2

4.6.3

Equipment tested to category A1 & D1

Tested to -20oC Operating Low Temperature

Tested to -55oC Ground Survival

Tested to +70oC Operating High Temperature

Tested to +85oC Ground Survival

Test not Applicable

50,000 feet

50,000 feet

-15,000 feet

Temperature Variation

5.0

Tested to Category C

Humidity

6.0

Tested to Category A

Operational Shock and Crash Safety

7.0

Operational to Para. 7.2.1

Crash safety to Para. 7.3.1 (impulse)

Vibration

8.0

Tested to Category M & N

Explosion

9.0

Equipment identified as Category X, no test performed

Waterproofness

10.0

Tested to Category X, no test performed

Fluids Susceptibility

11.0

Equipment identified as Category X, no test performed

Sand and Dust

12.0

Equipment identified as Category X, no test performed

Fungus

13.0

Equipment identified as Category X, no test performed

Salt Spray

14.0

Equipment identified as Category X, no test performed

Magnetic Effect

15.0

Equipment is Category Z

Power Input

16.0

Tested to Category B

Voltage Spike

17.0

Tested to Category A

Audio Frequency Susceptibility

18.0

Tested to Category B

Induced Signal Susceptibility

19.0

Tested to Category A

Radio Frequency Susceptibility

20.0

Tested to Category T

Radio Frequency Emission

21.0

Tested to Category Z

Lightning Induced Transient

Susceptibility

22.0

Tested to Category X, no test performed

Lightning Direct Effects

23.00

Equipment identified as Category X, no test performed

Icing

24.0

Equipment identified as Category X, no test performed

REVISION & CHANGE NUMBER OF DO-160: REV D. DATED JULY 27, 1997