Section 3 Installation Procedures

3.1

GENERAL

The SAC 7-35 is supplied with a mounting tray and crimp type mating connectors. It is
important that the proper crimping tools and techniques be observed in attaching wires to the
mating connectors. Failure to do so could result in a failure in the connection and cause inter-
mittent or non operation of the SAC 7-35.

3.2

EQUIPMENT REQUIRED

3.2.1 Supplied

SAC 7-35 System

705548-XX

Includes: SAC 7-35 Airdata Computer

305548-XX

SAC 7-35 Installation Manual

305586-00

SAC 7-35 Installation Kit, Electrical

305588-00

15 Pin Connector Hood

305208

2 each 25 Pin Connector Hoods

305437

25 Pin Female Connector w/Crimp Pins

305583

25 Pin Connector w/Crimp Sockets

305720

15 Pin Male Connector w/Crimp Pins

305721

SAC 7-35 Installation Kit, Mechanical

305589-00

Mounting Tray

305557

Knurled Hold-down Nut

305558

STP 78 OAT Probe

305561-91

OAT Probe Installation Kit

305595-00

Mounting Nut

305560-03

Mounting Lock Washer

305050-10

Fiber Shoulder Washer

305587-03

Flat Fiber Mounting Washer

305581-04

9 pin RS 232 to 6 pin DIN adapter cable

305580

3.2.2 Required But Not Supplied

Number 6-32 Mounting Screws, 3 or 4 depending on your selected mounting option.
Static Port Fitting
Pitot Port fitting

3.3

MOUNTING TRAY INSTALLATION

The mounting tray is mounted to the airframe using either three or four number 6-32 screws.
The mounting hole pattern for the SAC 7-35 mounting tray contains five holes. For new instal-
lations, it is recommended that the four corner holes be used to mount the SAC 7-35 tray. The
fifth hole has been added to facilitate upgrades from some manufactures encoders. Refer to the
SAC 7-35 tray dimensions in Figure 3-1 to determine if the hole pattern of the removed system
match the hole pattern of the SAC 7-35 mounting tray.

14