The on/off switch, The zero switch, Unit of weight selection – Scientech S9000 User Manual

Page 5: The send switch

Advertising
background image

Figure 4 Front Panel

THE ON/OFF SWITCH

Press the ON/OFF switch (see Figure 4) and observe the turn on sequence shown in Figure 5. During this sequence the balance

is doing an automatic systems checkout to insure it is functioning properly.

If your balance was purchased with the optional 9000-INT motorized internal calibration weight, all objects on the stainless steel

pan must be removed before turning on the balance using the front panel ON/OFF switch. Press the ON/OFF switch and observe

the turn on sequence shown in Figure 5. With the 9000-INT installed, the balance will then load the internal weight on and off

the weighing sensor in order for the internal weight to be positioned correctly. Please wait until all weight readings have stopped

changing, the “OK” annunciator appears, and the motor is silent before zeroing the balance and starting weighing operations.

Figure 5 Turn On Sequence


THE ZERO SWITCH

Pressing the ZERO switch (see Figure 4) at any time returns the display to zeros. When a weighing that has been zeroed out is

removed from the pan, a negative reading is displayed. To return to zeros, press the ZERO switch. An optional remote foot zero

switch is available as an accessory.

UNIT OF WEIGHT SELECTION

Pressing the MODE switch (see Figure 4) starts the unit of weight cycle as follows: grams(g), carats(ct), pennyweights(dwt), troy

ounces(ozt), and ounces(oz). When the desired unit of weight appears, press the MODE switch a second time to select that unit

of weight.

An optional, factory installed, user specified, custom unit of measure is available. If you have this special unit of measure feature

in your balance, (A) appears in the unit of weight cycle after ounces. Press the MODE switch to select this function.

THE SEND SWITCH


NOTE: Scientech balances are DTE (computer) devices. If communicating to another DTE device (ie computer), a
special Scientech RS232 cable (PN10697) is required. If you are communicating to a DCE device (printer), a modem cable
is required. Scientech offers an optional modem cable (PN10170) for your convenience.

Pressing the SEND switch (see Figure 4) sends the information on the display to an external device via the RS-232 interface.

You may send the time and date along with the weight reading when you press the SEND switch or you may send weight

readings automatically at user specified time periods (see the Bi-directional RS-232 Command Set, Type 4 Commands section for

details). Weight readings may also be sent to a computer or printer continuously every 200 milliseconds (see the RS-232 Front

Panel Configuration section for details). Weight readings may be sent automatically when the balance reaches stability (see

Selectable Filters section). An optional, factory installed, remote foot send switch is also available.

5

Advertising