2-11

Compaq Smart Array 3200 Controller Reference Guide

Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002

File Name: C-CH02.DOC Last Saved On: 12/7/98 8:33 AM

COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

Controller 1 Controller 2

ID5 ID5

ID4 ID4

ID3 d ID3

ID2 c ID2 z

ID1 b Array A ID1 y Array A

ID0 a ID0 x

Figure 2-5. Failed arrays removed; arrays on separate controllers

To restore an array to its original controller, make sure the conditions for
moving drives are met. Then:

IMPORTANT: These steps must be followed AS DESCRIBED. Any deviation
or mistake could result in the loss of all data across all moved arrays.

1. Power-down the system.

2. Move the array back to its original controller but retain its drive position

from the consolidated configuration.

3. Power-up the system.

4. Each controller will indicate a 1789 POST message, “Drives are

Missing.” Press F2 to fail the missing drives.

5. Run the Array Configuration Utility and remove the appropriate failed

arrays.

6. Reboot the system.