Slant/Fin VSPH-180 User Manual

Vsph, Ictory, Direct-vent sealed combustion boilers

Advertising
background image

IMPORTANT

READ ALL OF THE FOLLOWING

WARNINGS AND STATEMENTS

BEFORE READING THE

INSTALLATION INSTRUCTIONS

WARNING

LIQUEFIED PETROLEUM (L.P.)

PROPANE GAS-FIRED BOILERS

Installation location ONLY as permitted in paragraph

entitled "LIQUEFIED PETROLEUM (L.P.) PROPANE

GAS-FIRED BOILER LOCATION" on page 4 of this

instruction book.

The above warning does not apply to NATURAL gas-

fired boilers.

The installation must conform to the requirements of

the authority having jurisdiction or, in the absence of

such requirements, to the National Fuel Gas Code,

ANSI Z223.1-latest edition. The installation must also

conform to the additional requirements in this Slant/Fin

Instruction Book.

In addition where required by the authority having juris-

diction, the installation must conform to American

Society of Mechanical Engineers Safety Code for

Controls and Safety Devices for Automatically Fired

Boilers, No. CSD-1.

WARNING

This boiler, gas piping and accessories must be

installed, connected, serviced and repaired by a

trained, experienced service technician, familiar with all

precautions required for gas-fired equipment and

licensed or otherwise qualified, in compliance with the

authority having jurisdiction.

WARNING

The venting system of this boiler is under positive pres-

sure. Leakage from this system can be hazardous and if

not avoided can result in death or serious injury. In addi-

tion to the recommendations within this manual and the

User’s Information Manual, the venting system, from the

blower to the outdoor discharge, must be carefully

checked annually by a qualified service agency.

This manual must be left
with owner and should be
hung on or adjacent to
the boiler for reference.

V

ICTORY

VSPH

INSTALLATION AND OPERATING INSTRUCTIONS

Printed in U.S.A. 207

Part No. 455035 Publication No. VSPH-40 Rev. A

Heating Contractor

Address

Phone Number

Boiler Model Number

Boiler Serial Number

Installation Date

DIRECT-VENT SEALED COMBUSTION BOILERS

HOT WATER MODELS VSPH-60 THROUGH VSPH-180

GAS-FIRED CAST-IRON BOILERS FOR NATURAL AND L.P. PROPANE GASES

TABLE OF CONTENTS

Dimensions, Rating and Orifice Sizes ........................................2
Identification of Parts ..................................................................3
Installation Requirements ...........................................................4
Venting Application .....................................................................5
Boiler Room Air Supply and Ventilation......................................5
Flue gas Venting Requirements..................................................5
Vent Material ..............................................................................5
Air Intake Material ......................................................................6
Flue and Air Intake Restrictions .................................................6
Non-Direct Vent Installation ........................................................8
Sidewall Venting, Non-Direct Vent ..............................................8
Vent Termination Location and Clearance ..................................8
Non-Direct Vent Vertical Venting .................................................8
Direct Vent Installation ................................................................8
Sidewall Venting, Direct Vent ......................................................8
Vent/Air Intake Termination Installation.......................................8
Direct Vent, Venting and Air Intake through a Roof ..................13
Venting and Air Intake Regular Inspection ...............................15
Gas Piping ................................................................................15
Electrical Wiring ........................................................................15
Multi Zoning ..............................................................................18
Water Piping .............................................................................18
Wiring Diagram .........................................................................16
Operating Instructions...............................................................19
Gas Input Rate Adjustment ......................................................20
Boiler Control ............................................................................22
Sequence of Operation.............................................................21
Status of Indicator Lights (LED’s) .............................................22
Safety Check ...........................................................................23
Care and Maintenance .............................................................24
General Troubleshooting Guide ...........................................25-27

®