SerialGate

User Guide

Menu

Default

Description

Local Port

4001

Set the socket number for the port. TCP server and UDP server

operation mode makes use of this port for awaiting network socket

connections.

Target IP

0.0.0.0

In TCP Client, UDP Client mode, set the IP address of the target

device.

Target

Port

4001

In TCP Client, UDP Client, set the port number of the target device.

Latency

Time

0

This needs to be set when consecutive data from the given serial

port needs to be transmitted to socket at once.

For example, if 100 bytes of character string are to be transmitted

from the serial device to a server through SerialGate, bypass is set

to 0 for the latency time. Although it provides immediate sending

through SerialGate, the server could be received a lot parts of

divided packets.

If the latency time is not 0, SerialGate will wait for the time and

check new data. If there is new data, SerialGate repeatedly wait for

the time. Otherwise, SerialGate will transfer the buffered data, but it

could not run in real time.

Baud

Rate

9600 bps

Set serial communication speed

(Options: 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400,

57600, 115200, 230400, 460800, 921600 bps)

Data Bits

8

Fixed to 8.

Stop Bits

1

Set the number of stop bits (Options: 1, 2)

Parity

No

Set parity bit check scheme. (Options: No, Odd, Even)

Flow

Control

None

Set the flow control scheme.

(Options: None, RTS/CTS)