Solvline SG-3011DCL232 V1.0 User Manual

Page 30

Advertising
background image


SerialGate

User Guide

connectivity problems). If the IP address is not correct, then check whether the loading

procedure was properly executed.

Also verify that the host computer and SerialGate are using the same subnet masks (for

example, if SG-3011DCL/232 has a subnet mask of 255.255.255.0, the host must have the

same subnet mask) or that the router is properly configured to pass data between the two

devices.

If the wrong IP address is loaded, check your network for DHCP server, and make sure that

the server is not set up to load wrong IP addresses into SG-3011DCL/232.

Troubleshooting Windows Problems

If you are having trouble accessing the connected serial device through Windows,

ensure you can ping SG-3011DCL/232 using the command PING x.x.x.x, where x.x.x.x

is the IP address of SG-3011DCL/232. If you cannot ping SG-3011DCL/232, you will not

be able to access the serial device.

If you are running COM port redirector and the software reports an error, verify that the

correct virtual COM port is being used when the application runs. Verify that your

application’s COM port settings have been changed to use the virtual COM ports.