2 hardware install and recovery, 2 hardware install and recovery -2, Hardware install and recovery – Solvline Eddy DK Ver 2.20 User Manual

Page 68

Advertising
background image

Chapter

9.

Appendix

9-2

9.1.2

Hardware Install and Recovery


Connect LAN port of computer and that of DK board using LAN cable.
Connect debug port and computer’s serial cable using serial cross cable and use minicom to connect to
computer’s serial port. Configure computer’s serial port setting to 115200 bps, 8 data bit, No parity, 1 stop
bit and power on Eddy DK.

After power on the following messages will be printed to minicom.
When these are printed, press enter to enter into bootloader. The below image shows status after entering
bootloader.

You can recover by copying OS, firmware, and config image to flash memory in bootloader.

To upgrade OS, firmware, and config image file, you have to configure Eddy’s virtual IP address and TFTP server’s

IP address in bootloader.

You can use “printenv” command to check the current configuration of Eddy and TFTP server’s IP address

configured in bootloader.

U-Boot 1.2.0 (Oct 3 2007 - 17:07:46)

DRAM: 32 MB

SST : 39VF3201

Flash: 4 MB

In: serial

Out: serial

Err: serial

End of Autonegotiation

Hit any key to stop autoboot: 0

U-Boot>

Advertising