Specialty Concepts MARK/22 User Manual

Specifications, Recognized by underwriters laboratories (ul), Installation and instruction manual for the

Advertising
background image

IMPORTANT NOTE ABOUT TECHNICAL SUPPORT

THIS MANUAL PRESENTS ANSWERS TO 99% OF ALL OF THE TECHNICAL QUESTIONS THAT WE RECEIVE. PLEASE READ IT THROUGHLY TO
ANSWER QUESTIONS ABOUT THIS PRODUCT OR ABOUT SOLAR SYSTEMS IN GENERAL. IF YOU STILL HAVE QUESTIONS, PLEASE CONTACT
YOUR PROFESSIONAL SOLAR DEALER OR VISIT OUR WEBSITE FOR ADDITIONAL ASSISTANCE. THE AMOUNT OF ASSISTANCE THAT
SPECIALTY CONCEPTS, INC. IS ABLE TO PROVIDE OVER THE PHONE DIRECTLY TO END-USERS IS LIMITED.

OUR WEBSITE IS THE BEST PLACE FOR ANSWERS TO YOUR QUESTIONS ABOUT OUR PRODUCTS AND PV SOLAR SYSTEMS

INSTALLATION AND INSTRUCTION MANUAL FOR THE

MARK/15, MARK/20, MARK/22

SPECIALTY CONCEPTS, INC.

8954 Mason Ave. Chatsworth, CA 91311 USA

Web-site: www.specialtyconcepts.com

The Ideal Charge Controller for Home, RV, Marine, and other Solar Systems.

F E A T U R E S

IDEAL SOLAR CHARGING

Compatible – Works with almost all types of batteries and solar

panels

Efficient – Over 99% efficiency when charging

Full Charging – Ensures that the batteries are always topped off

Battery Safe – Charging method maximizes battery life

Reduced Maintenance – from healthy charging and reliable operation

OVER-CHARGE PROTECTION

High Voltage “Shut-off” - shuts off only when battery is full

Robust Circuitry – Control function 100% solid state.

HIGH RELIABILITY

Simple, rugged electronics – low component count and streamlined

design ensure long term reliability

No Minimum Voltage Required – Can charge a dead battery


FEATURES

Digital Voltage and Current – Accurate readout for battery and solar panels

Status Lights – Colored Battery condition bar-graph with “CHARGING” and

“CHARGED” lights

Adjustable Set-point – Easily adjusts to higher or lower voltages

Reverse leakage protection – Prevents power loss at night.

Over-current & Incorrect Wiring Protection – Array and Battery fuse

Terminal Block – for sound and easy wire connections.

Mounting Options – Can mount flush or onto a wall (with accessory box)

Environmental Protection – Circuit board is conformal coated to protect

against condensation.

SYSTEM COMPATIBILITY

Minimum RF Noise – Low switching frequency minimizes electronic noise

Protection from External RF Noise – Can operate with noisy inverters



































































Copyright 11/2002-A Specialty Concepts, Inc.

Specifications

PARAMETERS UNITS

MARK/15-12

MARK/20-12

MARK/22-12

Nominal Voltage

Volts

12

Array Voltage, Max (Voc)

Volts

26

Charging Current, Continuous (Isc) (MARK/15,20,22)

Amps

15, 20, 22

Charging Current, Max (60 seconds) (MARK/15,20.22)

Amps

20, 25, 27

Operating Voltage at Battery, Min

Charge

Control

Volts

0

LCD

Metering

Volts

7.8

LED

Bar-graph

Volts

10.5

Current Consumption

Quiescent (Tare)

Milliamps

8.8

Charging (with LED Bar-graph off)

Milliamps

12.8

LED Bar-graph Milliamps per LED

5

Charge Termination, Factory Set (1)

Volts

14.4 + .2

Charge Termination, Adjustable Range (2)

Volts

13.6 – 15.3

Charge Resumption, Factory Set (2)

Volts

13.0 + .2

Voltage Drop, Array to Battery

Controller Volts per Amp

0.05

Controller and 2 fuses Volts per Amp

0.08

LCD Meter Accuracy

DC

Voltage

/DC Current

0.5 %/1%

Operating Temperature Range

°C (°F)

-30 to 50 (-22 to 122)

Storage Temperature Range

°C (°F)

-40 to 70 (-40 to 158)

Notes:

(1) This is not a constant voltage controller.The batteries will drop below this voltage when completely charged.

(2) The Charge Termination / Resumption span is fixed. The Resumption set-point changes as the Termination set-point is
adjusted.

Recognized by Underwriters Laboratories (UL)

Meets all requirements for UL 1741 (MARK/15 ONLY).

NOTE: NOT ALL MODELS ARE CERTIFIED. REFER TO LOGOS ON PRODUCT (BACK) AND BOX LABLE FOR CERTIFICATIONS.