Mark, Template, For flush mounting) – Specialty Concepts MARK/22 User Manual

Page 9

Advertising
background image

MARK

/

(

15,20,22

)

TEMPLATE

(for flush mounting)

TOOLS AND MATERIALS NEEDED:

Slotted screw

driver, Wire cutter/strippers, Key

hole saw

or saber saw

, Pencil, scrat

ch aw

l or other marker

Wire of proper gauge to run from the panels, to the MARK/(15,20), and to the battery

(See

INSTALLATION INSTRUCTIONS #6: WIRE TYPE / SIZE

)

Mounting fasteners of appropriate ty

pe for w

all material

Included are four 3/4 - #6 screw

s and a spare fuse (20 amp

AGC for the MARK/15). (25 amp AGC for the MARK/20,22).

A

lso for Flush Mounting:

A

lso for w

all mounting: (MA

RK/(15,20,22) w

ith 4X7 BOX):

Drill w

ith 3/32" and 3/8" bits

1/2 inch Romex

strain relief clamps

Installation steps:

1. Tape template to surface where t

he MARK/(15,20,22) is to be installed.

2. Punch “Mounting Holes” and “Cutout Corner Holes” with nail or awl.

3. Remove template. Drill “Cutout Co

rner Holes” with 3/8” drill. Dr

ill “Mounting Holes” with 3/32” drill.

4. Connect outside edge of “Cutout Corner Holes” with a pencil line.

5. Use suitable saw to cut along pencil line.

6. Make electrical connections

. (Refer to instruction manual)

7. Mount the MARK/(15,20,22) to wall using supp

lied wood screws or other appropriate hardware.

Mounting Holes

(1 of 4 )

Cutout Corner Holes

(1 of 4 )

Cutout Outline

Advertising