SOLAR PANEL PROBLEMS:

- Refer to this section to help diagnose potential

problems based on panel performance.

CASE

PANELS

SEE CASE NOTE(S)

1

Less charge than expected

See Panel Case 1

Panel Case 1 - The panels should generate a charge current close to their max. power

current as presented in their specifications. To reach this level assumes that all
conditions are ideal. If the panel performance as measured at the panel inputs on the
SC3/10 controller is much lower, consider the following potential problems.

••

Solar Panel Problem - Panels may be dirty, not aligned or other problem. Panel

may have shadows crossing it. The panels could be configured incorrectly or be
defective. See Problem with the Solar Panels (Help Note #6)

••

Bad Panel Connection to the Controller - See BAD CONNECTION: PANEL (Help

Note #8).