Pin

Name

Description

1

+EX

+ Excitation voltage (+10 VDC)

2

+SN(+EX2) + Sense line

3

+SG

+ Signal line

4

-SG

- Signal line

5

-SN(-EX2)

- Sense line

6

-EX

- Excitation voltage (GND)

7

SHD

Shield

8

+SG2

Do not connect

9

-SG2

Do not connect

The load cell interface connector is “P4” on the circuit board,

located in the lower left hand corner.

Connecting External Power Supply

NEMA 1 enclosures are supplied with a transformer power supply, which plugs into the wall.
Power Required – 117 VAC +/- 10 VAC, 60 Hz

NEMA 12 and NEMA 4 enclosures are supplied with a 6’ power cord with a standard 3-prong
connector.
Power Required – 117 VAC +/- 10 VAC, 60 Hz.

Desk enclosures are supplied with a transformer power supply, which plugs into the back of
the instrument and the transformer plugs into the wall.
Power Required – 117 VAC +/- 10 VAC, 60 Hz

Mounting brackets are supplied with a NEMA 1 standard and NEMA 4 stainless steel
enclosures

.

(