Jumper settings – Sterling Scale 820 User Manual

Page 6

Advertising
background image

DW800/820 Operation Manual

Jumper Settings

In order for the 800/820 to operate as desired hardware, Jumpers must be set properly.
Most of the jumper setting’s are set correctly at the factory and never need to be altered, but
occasionally there is a need to alter a jumper setting, therefore they are shown below

Jumper List

Number

Name

Setting

Description

J1

Back light

On

Back light on

Off

Back light off

J2*

Load Cell Sense (+)

On

Not using load cell sense wires (+)

Off

Using load cell sense wires (+)

J3*

Load Cell Sense (-)

On

Not using load cell sense wires (-)

Off

Using load cell sense wires (-)

J4*

EPROM

256

Use 27C256 EPROM

512

Use 27C512 EPROM

J5

Ground

On

Chassis ground tied to digital ground

Off

Chassis ground not tied to digital ground

J6

RAM

2K

Use 2K RAM

8K

Use 8K RAM

J7

Not available

J8

NTEP/CTS

NTEP

Enable NTEP operation

CTS

Enable CTS flow control

J9

RAM

8K

Use 8K RAM

32K

Use 32K RAM

*NOTE: Jumpers J2 and is J8 must both be either connected or disconnected to avoid

improper weighing and/or possible damage to the indicator.