WIRING

YELLOW BLACK FOR NEGATIVE IGNITION OUTPUT: (Relay and/or Module not included )

YELLOW/BLACK

85

86

30

87

3rd IGN

(If needed)

IGN SW.

OR

ANTI-THEFT/

MODULE

+12V CONSTANT

OR

TRANSPONDER

Diode isolate

if using both!

ANTI-GRIND/STARTER DISABLE OUTPUT: (Relay not included)

TO

IGN 2

ENGINE

ACC

START

CUT

BROWN

YELLOW/BLACK

86

85

MAKE CERTAIN TO CONNECT "BROWN" START OUTPUT WIRE TO

STARTER SIDE OF ANTI-GRIND/START DISABLE RELAY.

IGN 1

MAKE SURE 86 TERMINAL HAS POWER WITH IGNITION ON AND CRANK

IGNITION