5.10.2. Mandatory Safety Stops
When the ascent rate exceeds 10 m/33 ft per minute continuously for more than five
(5) seconds, the microbubble build-up is predicted to be more than is allowed for in
the decompression model. The Suunto RGBM calculation model responds to this by
adding a Mandatory Safety Stop to the dive. The time of this Mandatory Safety Stop
depends on the severity of the ascent rate excess.
The STOP sign is shown in the display and when you reach the depth zone between
6 m and 3 m/20 ft and 10 ft, the CEILING label, ceiling depth, and the calculated Safety
Stop time also appear in the display. Wait until the Mandatory Safety Stop warning
disappears. The total length of the Mandatory Safety Stop time depends on the seri-
ousness of the ascent rate violation.

WHEN CEILING AND STOP ARE

DISPLAYED, MAKE A ONE MINUTE

MANDATORY SAFETY STOP IN THE

DEPTH ZONE BETWEEN 6 M AND 3 M.

You must not ascend shallower than 3 m/10 ft with the Mandatory Safety Stop warning
on. If you ascend above the Mandatory Safety Stop ceiling, a downward pointing arrow
will appear and a continuous beeping starts. You should immediately descend to, or
below, the Mandatory Safety Stop ceiling depth. If you correct this situation at any
time during the dive, there are no effects on the decompression calculations for future
dives.