TB0349A

Page 6 of 12

09/22/05

+VDC Switching examples

Must cut AUX P option resistor

HORN

RING

SWITCH

+VDC

AUX

SPLIC E

HORN

RING

SWITCH

+VDC

AUX (Add re sistor to GND)

Added

SPDT

Switc h

HORN

HORN

-VDC

switching

example

MOMENTARY

FOOT

SWITCH

AUX

ADDED RESISTOR FOR

POSITIVE SWITCHING

S

P

KR

S

P

KR

PO

S

PO

S

RA

D

RA

D

AU

X

CU

T

NE

G

NE

G

• • • • • • • • • •

Added r esistor to GND

1K @ 1/4 watt

-VDC

switching

example

ADDED

DOOR

SWITCH

CUT

+VDC Switching

Example

Must cut CUT P option resistor

DOOR

SWITCH

+VDC

CUT

SPLIC E

DOME
LIGHT



Auxiliary Input Connection - The Auxiliary
Input allows activation by an external source
of either the Horn or Man/Phsr function. The
adjacent diagram shows three connection
examples. See the INSTALLER-
SELECTABLE OPTIONS section for
programming details.
If positive switching is used for the auxiliary
(AUX) Input and the connection to the
destination device (horn) is removed a
resistor (1 supplied) must be added between
the AUX input and ground for proper
operation. A symptom of this problem is
continual activation of the auxiliary function
when the horn ring is not pressed.
NOTE: Permanent disconnection of the
vehicle horn is NOT recommended.




















Cutout Input Connection - The Cutout Input turns off any
siren tone output when activated, and remains off until a control
is activated or changed. The adjacent diagram shows two
connection examples. See the INSTALLER-SELECTABLE
OPTIONS section for programming details.








Advertising