Light Control Connections

In addition to these instructions a label located on the bottom of the unit shows the light control switch connections.

Fuses / Breakers
The lighting control circuits of this unit are not fused. Automotive fuses or circuit breakers must be connected
between the power source and the unit properly rated for the circuit requirements. Failure to install proper circuit
breakers or fuses can result in damage to the unit and/or vehicle.


Lever Switch Connections

The following diagram shows proper connection of the lever switch leads located at the rear.

Note: Negative (NEG) connection must also be made on 10-Pin connector for proper operation.

YEL

GRN

BLU

RED

Circuit Breaker

or Fu se

60 AMP Max.

LOAD 1

LOAD 2

LOAD 3

+

BATT

-

Recommended

Wire Size

Amps

Size

5 - 10

#16

10 - 15

#14

15 - 25

#12

25 - 40

#10

40 - 60

#8

60 - 80

#6

Use next larger size

if longer than 10 ft.

Lever

Position

Turns

On

Off

All off

1

Load 1 only

2

Loads 1 and 2

3

Loads 1, 2 and 3