Section 6: Detailed Parameter Descriptions

UTILITY | I/O

The UTILITY / I/O Tab sets the analog and/or digital
input/output configuration. Below are descriptions of the
various parameters:

Voice / Aux Input
Selects the input source for the lead or aux path.

Voice / Aux Sens. and Analog Out
In combination, these parameters are used for attaining the
best possible dynamic range when using VoicePro with
analog devices. Voice / Aux Sens sets the maximum input
operating level. Analog Out sets the maximum output
operating level. Nominal values for use in a typical auxiliary
send configuration on a mixer would be 3dBu for inputs,
and 24dBu for outputs.

Digital Multi Out Mode
This parameter configures the functionality of digital output
channels 3 to 8 (digital channels 1 & 2 are always fixed to
master stereo output). The three options are as follows:

"Off": no output on channels 3 to 8

"Voices": Harmony voices 1 to 4 on channels 3 to 6, lead
voice on channels 7, VirtuaLead on channel 8.

"Blocks": stereo harmony on channels 3 and 4, stereo lead
on channels 5 and 6, stereo Multi-FX on channels 7 and 8.

Clock Mode
Set this parameter at "Normal Rate" when working with
sampling rates of 44.1K or 48K. For sampling rates of
88.2K or 96K, set the parameter to "Double Rate".

Clock Master
Synchronizes VoicePro's digital inputs to the clock rate
from "Internal", "Word Clock" or "Digital In".

Clock Rate
When Clock Master is set to "Internal", the Clock Rate
parameter sets the sampling rates based on the Clock

Mode. If the Clock Master Parameter is set to "Digital" or
"External", the Clock Rate Parameter sets the target
sampling rate to which VoicePro will lock.

Master Output Level
Sets the stereo output level to the stereo analog and digital
channels 1 and 2.