Tii 90-3 User Manual

Page 2

Advertising
background image

NOTE: Wires should be aligned to the
corresponding holes. Green wire to the
“T” (GRN) labeled wire guide and the
Red wire to the “R” (RED) labeled wire
guide.

9. Insert wires into wire guides at the same time

until they bottom out.

10. While holding wires in wire guides, terminate

rocker with thumb (lower rocker all the way).

11. Terminate additional pairs to rockers as

required.

12. Assure all rockers are in the down position

and close customer security cover.

13. Test for unit operation.

14. After wiring is complete, close and secure NID

cover (Figure 2).

Installing The 90-3 Sealed Bridging Module
Into A CAC 7600 Network Interface

1. Locate the Network Interface Device.

2. Unlock the cover (similar to Figure 2).

3. Identify the appropriate line position in the

NID.

4. Snap the bridging module into the adapter,

then into the base as shown in Figure 4.

5. Terminate wire leads (Tip/Ring) from the

bridging module to terminals on the existing
Customer Bridge Module.

6. Lift all CBM rockers to the open position as

shown (see Figure 1).

7. Hold the customer telephone wires between

thumb and index finger (approx. 1/8”
separation between wires).

NOTE: Wires should be aligned to the
corresponding holes. Green wire to the
“T” (GRN) labeled wire guide and the
Red wire to the “R” (RED) labeled wire
guide.

8. Insert wires into wire guides at the same time

until they bottom out.

9. While holding wires in wire guides, terminate

rocker with thumb (lower rocker all the way).

10. Terminate additional pairs to rockers as

required.

11. Assure all rockers are in the down position

and close customer security cover.

12. Test for unit operation.

13. After wiring is complete, close and secure NID

cover (Figure 2).

STEP 1

Load Bridging Module

Into Adapter

STEP 2

Load Module/Adapter

Assembly Into Base

Of Unit

Adapter

Bridging Module

Adapter

Locking
Bar Tab

CAC 7600 Base

Bridging Module

Figure 4

Advertising